Malfunctions of two-chamber refrigerators Indesit No Frost

Refrigeration equipment from the Italian company Indesit has become widespread in the Russian Federation due to the localization of production at the plant in Lipetsk. Malfunctions found in Indesit two-chamber No Frost refrigerators can be diagnosed by the owner, who independently determines the method of repair. Warranty equipment is recommended to be serviced at the manufacturer's service centers.

Malfunctions of the Indesit refrigerator and methods for eliminating them

Most Indesit refrigerators are two-chamber; using their examples, we will look at the malfunctions characteristic of these models. Signs of a malfunction of the Indesit refrigerator compressor are:

  • the unit operates noisily, with uncharacteristic knocking and whistling;
  • starts for a few seconds and stops;
  • does not produce cold.

Replacing a compressor and filling the system with refrigerant is an expensive, complex repair. This is caused by prolonged operation of the device in conditions that do not meet operating requirements or depletion of the resource.

The most common and less costly reason will be the failure of the thermostat. The manufacturer has determined the working life of the thermostat to be 5 years. Signs of a malfunctioning thermostat:

  • The temperature in one of the chambers does not hold.
  • The compressor may not turn on, but may run continuously.
  • The electromechanical thermostat does not make a characteristic click when the knob is turned to 0.

You can replace the temperature sensor yourself. The node is connected to the thermostat.

Why is the cooling mode not maintained in the chambers? If the compressor does not turn on, you need to check the contacts of the start-up relay. They may burn out or stick and will need to be replaced.

Long-term operation of the device is accompanied by gradual volatilization of freon. In case of mechanical damage to the evaporator, leakage due to corrosive wear at the junction of copper and aluminum tubes, in the door heating circuit, the gas quickly leaves the circuit. Lack of freon impairs the operation of the refrigerator. Heat dissipation is reduced. Signs will be an increase in temperature and the formation of a “fur coat” in the refrigerator. The circuit needs to be refilled with freon.

The refrigerator will operate with the same symptoms as a lack of freon if the capillary tube is clogged. The difference is determined by the temperature of the condenser and its heating zones.

A faulty board in an electronically controlled refrigerator paralyzes the operation of all systems. A breakdown occurs when there is a power surge in the network. To avoid problems, all devices with electronic control units must be connected through a voltage stabilizer.

For Indesit refrigerators with No Frost, malfunctions related to fan operation and ice thawing are possible. The electronic display displays code F04. The fan may stop due to freezing of the blades or a malfunction in the electrical circuit. To defrost the internal ice behind the wall and in the chamber, dry it, and start the fan, it takes at least a day. Ice builds up on the propeller if the ice defrost heater on the evaporator is not working. It turns on at the command of the thermostat. There may be a malfunction of the heating element, wiring, or thermostat. Error code F7.

Each refrigerator model has features in its design, cooling circuit, electrical and electronic control circuits. Let's look at the malfunctions that are typical for different Indesit refrigerators, why they don't turn on and don't freeze.

Typical breakdowns and methods of dealing with them

The owner of Indesit refrigeration equipment should familiarize himself with information about common types of problems that accompany the operation of their favorite unit.

The information will help you monitor the actions and evaluate the work of refrigeration technicians, not all of whom are conscientious, or carry out simple repairs yourself.

Signal: relay not working

If the temperature in your refrigerator or freezer gradually rises and the cooling level cannot be achieved, the start relay has most likely failed.

This element regulates the operation of the compressor, which is needed so that freon moves through the system at the required speed. It is recommended to check the motor contact terminals.


If the refrigerator does not turn on, you first need to check its electronic circuits outside and inside, although the cause of such a breakdown may also be a malfunction of the start relay (+)

In conditions of high humidity, carbon deposits can accumulate here, which interferes with the operation of the device. Another important point is the correct connection of system elements.

If it is carried out with flaws (as happens when carrying out unprofessional repairs), disturbances in the operation of the relay are quite possible. In extreme cases, the element may burn out due to a short circuit. In this case, the start relay will have to be completely replaced.

If the refrigerator starts for just a couple of seconds after being plugged in, and then immediately turns off, this may also be due to a faulty relay, but there are other options. It is also recommended to check the wiring and electronic control unit.


Oxidation of the contacts can lead to a loss of power supply to the refrigerator. It is enough to disconnect them, clean them and connect them again to restore normal operation of the device

Before replacing the relay, experienced craftsmen first check (ring) the motor winding. If it is faulty, efforts to replace the relay will not yield results. You should first repair the engine if such a breakdown is detected after diagnosis.

Ice that shouldn't exist

The No Frost system, which is equipped with almost all models of Indesit refrigerators, allows you to create cold without ice and frost. If it still appears on the walls of the chambers, it means that the device is not working correctly. This type of problem occurs quite often, and the usual cause is violation of operating instructions.


If frost appears on the walls of a refrigerator with a No Frost system, it may simply be time to defrost it. If there is a lot of ice or it appears frequently, a thorough diagnosis will be required.

Although icing should not occur in the chamber, periodic defrosting is still necessary and should be done every seven months. If the appearance of frost is associated with a long lack of maintenance, you just need to defrost the refrigerator in accordance with the instructions.

If defrosting does not help, and the amount of “snow” inside accumulates too quickly, you should check the condition of the temperature sensor and capillary tube. The tube may have become clogged or dislodged. In this situation, it is better for inexperienced craftsmen to contact a service center.

Insufficient chamber sealing

A simple breakdown is wear or damage to the sealing layer on the refrigerator door. If the door is not closed tightly, the device will work under increased load, which can cause a variety of breakdowns.

If damage to the rubber is detected, you should simply replace it as soon as possible. This is a simple operation that you can do yourself. New rubber gaskets can be secured around the perimeter of the door using glue or epoxy resin.


A worn rubber gasket on the refrigerator door must be immediately replaced with a new one in order to eliminate the cause of its leaky fit and cold leakage

Fan failure

The error code F04 indicates that the fan is faulty. To understand the nature of the problem, you need to “ring” the electrical circuit of the fan itself, as well as its control board. You can simply connect the device to the network. If the blades of the device do not rotate, it should be replaced.

If there is movement, you need to deal with the electronic board. To replace it, it is better to take exactly the same fan, designed for a specific refrigerator model.

Usually it can be ordered through a service center. Replacing the control board and setting it up can only be entrusted to a technician who has undergone training and internship in repairing refrigeration equipment of this brand.

Broken defrost heating element

This fault is usually indicated on the panel by error code F07. First you need to make sure that there is resistance in the circuit, and then inspect the fuses. These procedures are not complicated, they will allow you to determine whether the heating element has really burned out or whether the problem is in the fuses.

If the fuse is faulty, you just need to replace it. When the fuses are in order, all that remains is to replace the defrosting heating element. It is better to use the help of an experienced craftsman for this; independent repairs of this type rarely end successfully.

Compressor troubleshooting

A refrigerator compressor failure is a death sentence; you will have to buy and install a new device. There are two main reasons for such a malfunction: voltage drops in the network or normal wear and tear. Replacing a compressor is not a cheap procedure; sometimes it’s easier to add a little money and buy a new model of refrigerator.


It is better to entrust the elimination of complex faults, such as repairing motor windings or replacing a compressor, to an experienced professional from a good service center

It is not difficult to understand that the engine has broken down, since in operating condition it makes a characteristic noise. There is no sound, which means the device is faulty, i.e. Freon does not circulate, heat exchange does not occur, and the temperature does not drop. You need to check the power cable, it may be damaged.

If the reason is not in the wires, you will have to either repair the compressor or completely replace it. It also happens that it is not possible to immediately determine the exact cause of the breakdown.

For example, the engine is running, but the temperature inside the refrigerator remains too high. You will have to invite a repairman to conduct an in-depth diagnosis of the device’s condition.


The compressor is one of the main elements of any refrigerator; it circulates refrigerant throughout the system and moves thermal energy from the chambers to the outside.

Another good reason to seek professional help is excessive or uncharacteristic noise. If your refrigerator is making too much noise when the compressor is running, it may simply not be level.

You need to arm yourself with a level and correct the position of the device using the adjustable legs. If the noise continues, there may be a more serious problem. Modern Indesit refrigerators operate almost silently.

Preventing refrigerant leakage

Freon leaks happen quite often; the following signs may indicate a possible lack of refrigerant in the system:

  • air cooling in the chambers is insufficient;
  • Frost regularly appears on the walls;
  • a bulge appeared on the back wall of the refrigerator;
  • breaks in compressor operation have become too short;
  • the compressor runs continuously.

In such a situation, it is important to accurately determine that the Indesit refrigerator does not freeze effectively precisely because of a freon leak, then eliminate the cause of the breakdown and pump a new portion of refrigerant into the system.

For an experienced master this is an ordinary procedure, but for a non-specialist it is better not to interfere with the operation of complex equipment, so as not to completely ruin the situation.


To top up the system with refrigerant and identify the causes of its leak, you will have to unsolder the circuit and fill it with air under pressure

Freon leaks out if there is damage in the system, in other words, a hole or crack. It can be almost invisible. Double-chamber refrigerators are more susceptible to such breakdowns than simple models with a single chamber. The cooling system of the upper section and the freezer, which is located below, are connected by a heat pipe.


To fill the refrigeration circuit with freon, it is better to invite an experienced specialist who will carry out the work correctly and provide quality guarantees

Moisture often condenses on this element due to temperature changes. As a result, corrosion processes are activated, holes appear, and freon leaks out. The gas does not have a characteristic color or odor, so the problem becomes obvious only if the leak affects the operation of the device.


A soap solution applied to the surface of the tubes will help to detect the location of a refrigerant leak in the refrigeration circuit. This is the only way to identify microcracks

There is no need to worry about health safety. Refrigerants are inert, and their quantity in a typical refrigerator is not very large. Even if absolutely all the freon leaks out, the residents of the house will not face any sad consequences. Sometimes the location of a freon leak can be detected visually, but this is not always the case.

To identify circuit damage, you need to:

  1. Open the sealed compressor tube.
  2. Pump out the remaining freon in the system.
  3. Fill the circuit with normal air under low pressure.
  4. Determine the location of damage by the characteristic hissing sound.
  5. Solder the hole or crack.

After this, it doesn’t hurt to fill the circuit with air again to check the quality of the soldering and make sure there are no other damages. After this, the sealed circuit is filled with fresh refrigerant. Our recommended article will introduce you to the steps and rules for performing this procedure.

Breakdown of current to the housing

If the refrigerator body begins to shock, this is a reason for serious concern and the beginning of immediate repair work. A more or less experienced electrician can initially do without a technician. First of all, the device must be immediately disconnected from the power supply.

The so-called housing breakdown usually occurs due to damage to internal or external electrical wiring. First, you can take a multimeter to measure the insulation resistance of the refrigerator. After disconnecting from the electricity, you need to inspect all the wires.


Sometimes, even with such an inspection, you can find the place where the wire has come loose or where the insulating layer is damaged. All that remains is to completely replace part of the wiring or insulate the damaged area. Insulation is a temporary measure; experienced craftsmen recommend replacing the entire wire, it’s more reliable.

If the inspection does not produce results, you need to check all the wires one by one with the device in order to identify the malfunction and eliminate it. This is done simply: the grounding wire of the device is closed to the body of the refrigerator, and the phase wire is connected to different lines.

Usually they check the lines supplying the compressor, thermostat and relay, and find the location of the damage. If it was not possible to identify the cause of the breakdown, you should immediately invite a repairman; you should not plug in a refrigerator with such a fault.

The appearance of an unpleasant odor

If there is an unpleasant smell in the refrigerator, which is not caused by the fact that spoiled food is stored inside, there is no need to worry. Most often, this situation is created as a result of non-compliance with operating rules, and not technical breakdowns, i.e. you won't need a master.


The constant presence of foreign odors in the refrigerator is usually caused by violation of operating rules. You need to defrost the device, wash it, wipe it thoroughly and ventilate it.

Such aromas appear very often soon after defrosting the refrigerator, if its walls were not wiped thoroughly enough. To combat the smell, the procedure will have to be repeated, but during defrosting, you need to leave an open container inside.

A mixture of plain water and lemon is poured into it. After defrosting, all internal surfaces should be wiped with a cloth soaked in another portion of water and lemon juice. Then it is recommended to leave the refrigerator closed for about a quarter of an hour or a little more.


After turning off the refrigerator, you need to wipe all internal surfaces dry. It is recommended to allow time for the device to dry and ventilate.

After this, all surfaces are thoroughly wiped dry and the chambers are left open for ventilation for about five to ten hours, i.e. for the whole night. A typical problem for many brands of Indesit refrigerators is icing of the channels through which air is exchanged.

As a result, the inside of the device cools too slowly. To correct the situation, it is usually enough to simply defrost the device regularly. Unpleasant odors can also come from a clogged drain pipe, which just needs to be thoroughly rinsed during defrosting or blown out with a stream of compressed air.

Problems with the backlight in the camera

If the backlight in the refrigerator is broken, most likely the standard 15 W lamp simply burned out. To replace it, you need to remove the lampshade, which is held in place by a mounting bolt. Then the burnt out lamp is unscrewed, replaced with a new one, and the lampshade is put back in place.


Replacing a burnt-out lamp is one of the simplest operations. You need to remove the lampshade, unscrew the old lamp, install a new one and return the lampshade to its place

To choose the right lamp, it is better to take the burnt-out element to the store and pick up exactly the same one. If replacing the lamp did not give anything, then the problem is more serious, it’s time to call a technician.

Refrigeration unit does not turn on

It also happens that the refrigerator simply stops turning on, i.e. the starter does not work. It is recommended to start looking for reasons not inside, but outside. The problem is caused either by damage to the power cable or by a lack of current in the network. The cable needs to be replaced or repaired.

If the central power grid is turned off for some reason and the refrigerator is needed, it can be connected to an alternative source of electricity. Sometimes the refrigerator does not turn on due to frequent voltage fluctuations in the network. When the network is less than 190 W, the device does not operate until normal characteristics are restored.

Using a stabilizer will help solve the problem. This situation cannot even be considered a breakdown, since the device correctly responds to changes in operating conditions and protects other elements from serious damage.

Incorrect defrosting of the chamber

Problems with defrosting the refrigerator may arise due to a breakdown of the defrost button, which is found in many models.

As a result of wear or excessive mechanical stress, the button becomes stuck and the refrigerator either goes into an endless defrosting cycle or stops defrosting altogether. In any case, you need to remove the faulty button as quickly as possible and replace it with a new element.

Malfunctions of the refrigerator thermostat Indesit C132G016

The model is two-chamber, with 1 compressor, electromechanical control. Condensate is removed from the refrigeration chamber by drip; the freezer requires manual defrosting. The refrigerator is very reliable; during normal operation it operates without repair for more than 10 years.

A typical failure in the model is the failure of the thermostat. This is a housing part with internal relay contacts and a membrane. If the unit malfunctions, the refrigerator compartment does not work, and the temperature in the freezer drops. Due to the inability to analyze, the sensor sends incorrect commands to the module. The compressor may run without stopping, which will lead to its breakdown. The motor does not turn on if the sensor does not give a start command.

The thermostat cannot be repaired and must be replaced. To do this, disconnect the refrigerator from the network and replace the sensor according to the operating instructions. We suggest watching a video on replacing the thermostat on a refrigerator.

Unpleasant smell

Such odors may appear inside the refrigerator due to the fault of users, when placing products with strong odors, when the freezer compartment is not wiped dry after defrosting. The smell is removed quite easily.

  1. Remove all food from the refrigerator compartment.
  2. Place a bowl of water and lemon juice in this chamber at a ratio of one to one, close the door tightly and turn off the refrigerator to defrost the freezer.
  3. After defrosting, which will last several hours, wipe all the walls of the chambers and shelves with a mixture of lemon juice and water, leave closed for a few minutes, but no more than half an hour.
  4. Wipe the entire inside of the refrigerator with a dry, clean cloth. Lemon vapor and its juice not only remove odor, but also remove fat deposits and dirt from walls and shelves.

The refrigerator can be used no earlier than 5-10 hours, because it must be well ventilated. It is better to do this operation in the evening, before going to bed, and by the morning your refrigerator will be like new.

Malfunctions of the refrigerator Indesit C138NFG

Two-chamber combined refrigerator with one compressor and electromechanical control. The No Frost defrosting system is used in the freezer and a “crying” wall in the cold chamber.

The temperature control in the chambers is independent, thanks to the presence of a magnetic valve on the refrigerant line between the freezer and the refrigerator. Faulty components of the Indesit refrigerator of this model, when the temperature in the chambers is not maintained, can be:

  • freezer thermostat, if the required minus is not reached in the freezer;
  • upper chamber thermostat, if the temperature in the refrigerator is incorrect;
  • sticking of the switching magnetic valve;
  • Freon leak or compressor failure.

Elimination of the causes is possible after a complete diagnosis by service center specialists.

The condensate drainage system in the refrigerator may become clogged. Failure of heaters in the No-growth freezer system will result in icing. The fan will stop, clogged with ice. A non-working defrost timer will also lead to such consequences.

A specialist can find and fix the problem, but before doing this, you should defrost the lower chamber for 24 hours. During this time, the refrigerator blades will be freed, and it will be possible to check whether the No Frost electrical network is working properly.

First aid for the refrigerator

When a puddle forms under the refrigerator and the food in the freezer begins to thaw, this is an indication that the freezer is not freezing enough for some reason. Such a malfunction must be eliminated without delay, but this requires identifying the cause of the “critical” state of the refrigerator. In several options, it is possible to correct the situation on your own. Before calling, the technicians take the following “resuscitation” actions:

  1. Disconnect the unit from the power supply and leave to defrost for approximately 24 hours. Often, due to an insufficiently tight fit of the sash, ice forms on the walls, even with the No Frost system. At the same time, wet cleaning of the chambers is carried out. After thawing, check that the unit is connected to the network correctly - there should be no extension cords or tees. The upper chamber often stops freezing in model b18fnf refrigerators.
  2. Check the mode set on the regulator or display. It is likely that the settings are incorrect or the room is too hot, and the device is not able to cope with such a heavy load.
  3. The upper chamber may not function due to uneven floors. You can identify the problem using a glass filled with water (instead of a building level). When the liquid in the dish flows to one side, you need to level the unit by tightening the legs of the refrigerator and re-check whether the freezer is cooling.

If the chamber still does not start to freeze, then calling a refrigeration equipment repair specialist is a must.

Advice! When the problem has disappeared, we can say that it was simply a system failure of the electronics, but just in case, I recommend calling a technician for a full diagnosis.

Malfunctions of Indesit BIA 181 NF

The refrigerator is a two-chamber refrigerator with a bottom freezer and has energy efficiency class A. The device has one compressor with full No Frost in the chambers. On the forums, the model is described as reliable; malfunctions do occur, but the technicians advise you to pay close attention to maintenance.

A model with an external condenser mounted in the form of a grid above the motor will last longer if the heat exchanger is thoroughly cleaned of dust and pet hair once a year.

If the Indesit refrigerator does not freeze, malfunctions may be detected:

  • network damage or lack of power.
  • thermostat malfunction;
  • Freon leakage due to the appearance of fistulas in evaporators or refrigerant pipes;
  • plug in the capillary system.
  • failure of the motor-compressor.

The No Frost system in both chambers is located behind the wall of the refrigerator. Products are cooled by air flow, condensate is deposited inside the system. The main sign of a malfunction of the Indesit air-cooled refrigerator is the appearance of ice inside the chamber and an increase in temperature due to a violation of heat transfer.

After completely defrosting the chamber with the fan not working, it becomes clear:

  • defrost timer failed;
  • break in the heater power supply circuit;
  • The fan is broken.

If puddles form under the refrigerator, you need to check the integrity and serviceability of the condensate drainage system into the container installed on the compressor.

The appearance of frost in the refrigerator while the fan is running indicates a violation of the seal of the chamber. It is necessary to check the fit of the seal and its integrity. Adjust or eliminate door sagging. Choose a more correct operating mode. Optimally, select the middle setting.

Results

Each of the malfunctions of Indesit refrigerators requires timely diagnosis and repair by a specialist. When the upper chamber stops freezing, first make sure that this is not a software failure by allowing the refrigerator to thaw for 24 hours and restarting it. If these actions do not help, then call a service center for the repair of refrigeration equipment, since unskilled manual repairs can cause more serious damage.

It is possible to extend the operating life of the unit by maintaining the correct temperature conditions, defrosting the chambers in a timely manner and preventing compressor overloads. By following the rules in the instruction manual, it is possible to avoid unexpected and unnecessary costs for repairing an Indesit refrigerator.

Video: Indesit refrigerator - the refrigerating (main) chamber does not cool well

Refrigerator "Indesit" - the refrigerating (main) chamber is poorly cooled. We are repairing.

Watch this video on YouTube

Video: the freezer compartment of the INDESIT NO Frost refrigerator does not freeze

The freezer compartment of the INDESIT NO Frost refrigerator does not freeze, diagnostics and repairs

Watch this video on YouTube

Do you want to understand better than others?

  • Why the upper chamber in the Samsung No Frost refrigerator does not freeze - The Samsung refrigerator is a fairly successful household appliance in terms of design, which rarely fails in the next few years after its purchase. However, according to…
  • The freezer does not freeze or does not freeze well - the reason and recommendations from specialists to troubleshoot problems - Why might the freezer stop freezing? There are many parts that affect the operation of the freezer. Among them: The motor, which is directly responsible for the operation of the freezer. If…
  • The upper chamber of the refrigerator does not freeze, but the freezer works: causes of the problem and solution - Myths and fairy tales There are many articles on the Internet that give advice from incompetent people. They can name the following reasons why the main compartment of the refrigerator does not work: It’s not tight...
  • Breakdowns of Indesit refrigerators - During the operation of refrigeration units, breakdowns are possible due to the failure of individual parts. The most difficult ones manifest themselves in the fact that the devices completely stop...
  • The main malfunctions of household refrigerators "Stinol" by model - The Stinol refrigerator is a domestic brand with Italian roots. This equipment is quite reliable, the technical characteristics and other indicators of these units...

Refrigerator Indesit NBA18FNF – main faults

The refrigerator is two-chamber, with a bottom-mounted small freezer of 63 liters, energy efficiency class B. The chambers use No Frost defrosting.

The main cause of malfunction of the Indesit refrigerator of this model will be the failure of the thermostat, a device that ensures the maintenance of the set temperature in the cabinets. Signs of a malfunction are:

  • the refrigerator does not turn on, but there is light inside;
  • the compressor runs continuously;
  • in the cold chamber there is sub-zero temperature;
  • The compressor stopped freezing.

How to check the performance of the compressor, find the one you need for your freezer and refrigerator, and change it yourself; step-by-step instructions are provided in the video.

However, the master can find other reasons. These include a lack or absence of freon, clogging of the capillary tube with refrigerant breakdown products in reaction with oil, and compressor malfunction.

Why the Indesit refrigerator does not freeze - reasons

The cooling circuit may fail due to a malfunction of one of the parts. Most often, the cause is a lack or complete leak of freon in the Indesit refrigerator. A malfunction can be detected by the following signs:

  • the temperature in the freezer is maintained, and the refrigerator gradually increases;
  • the compressor hums incessantly;
  • gurgling of liquid is heard intermittently, the temperature continues to drop;
  • condenser - grill on the back of the refrigerator, cold;
  • After stopping to clear the ice, the freezer does not freeze, the compressor works, it is very hot.

Why did the Indesit refrigerator stop freezing after cleaning? It was enough to maintain the regime in the frozen chamber of the agent, and during a long period of inactivity the gas finally evaporated into a leak. The circuit may have been broken when cleaning the tubes mechanically.

Before filling the system with refrigerant, the technician will have to find the leak and possibly turn off the heating circuit. One of the signs of a fistula site is swelling of the chamber wall. There is a black oily stain around the hole.

Often, the Indesit refrigerator does not freeze well as a result of a clogged capillary tube. The white precipitate is a reaction product of freon and oil and clogs the capillary. The unit requires replacement or repair. It is rare, but sometimes the compressor is faulty. It does not create the required pressure in the gas environment.

The reason may be in the control system of the Indesit refrigerator. The compressor turns on and stops depending on the command of the thermostat, which controls the process using sensors and relays. The thermostat in a single-compressor apparatus is installed in the upper chamber. Therefore, when the start relay fails, the upper chamber does not freeze at first.

However, clients often complain that it gets very cold in the plus chamber. The reason is also a malfunction of the thermostat of the Indesit refrigerator. At this time, the walls of the chamber freeze over because the compressor works non-stop.

The Indesit refrigerator will not freeze well if the inside of the chamber is overgrown with ice, which does not conduct heat and acts as an insulator. At the same time, a coat of ice can disrupt the tight fit of the doors. Incoming jets of warm air will cause additional ice. When eliminating frost, you should check or clean the condensate drain hole in the drip defrost system. Make sure the defrost turns on and works.

You can determine that the Indesit refrigerator has started to work poorly by the constant operation of the motor or the absence of compressor starts. You should pay attention if the compressor turns on for seconds and turns off with a loud knock. It happens that the start relay clicks, but the motor does not turn on. But if the light in the chamber is on and the refrigerator does not turn on, start checking with the thermostat.

Refrigerator Indesit B16FNF – faults and their elimination

Giugiaro series refrigerator with bottom-mounted freezer. The device has electronic control. No Frost is used in both departments. There is a freshness zone. Adjust camera modes on the front panel at the same time. There is an indication of operating parameters and a signal in case of deviations or violation of the tightness of the circuit. The energy efficiency of the equipment is class B. The main malfunctions of the Indesit refrigerator of this model relate to the control system and the cooling circuit.

In a refrigerator, the electronic control system may fail due to power surges in the network. Therefore, the device must be connected through a stabilizer. The problem point is the full No Frost system. Most often you have to change the fan or the power supply to it. If water is leaking from under the refrigerator, you need to inspect the condensate removal system.

The Indesit No Frost refrigerator does not freeze

In the refrigerator, Indesit No Frost provides air cooling for the chamber. The cold is removed by forced blowing of the evaporator using a fan. The Indesit No Frost refrigerator does not freeze for possible reasons:

  • the evaporator does not freeze;
  • the evaporator is covered with ice, air does not pass between the tubes, defrosting does not work;
  • the fan is not working.

The refrigerant circuit may fail due to the reasons listed above. In No Frost, defrosting of the evaporator may stop due to a fuse, a malfunction of the heating element, or a failure of the system timer or fan. The root cause is a violation of the defrost cycle, followed by icing of the evaporator and breakdown of the spindle.

The accumulation of snow is accompanied by a crash and loud noise - the fan blades touch the icy surface. Continuing operation without eliminating the cause will result in motor damage.

Malfunctions of the refrigerator Indesit C132G

Freestanding refrigerator with electromechanical control. Manual defrosting is used for the freezer and drip defrosting for the refrigerator. The compact device is 167 cm high and has a volume of 241 liters.

The main malfunction of the Indesit refrigerator is that when the refrigerator compartment does not maintain the temperature, the lower cabinet does not freeze. There are several reasons, the main ones include:

  • malfunction of the thermostat in the upper chamber and the thermostat in the lower chamber;
  • absence or lack of freon due to a leak in the circuit or damage to the evaporators;
  • plugs in the capillary system;
  • failure of the motor-compressor or start relay.

But first of all, when you detect melted food, you need to check whether there is voltage in the power line and whether the power-on indicator on the refrigerator is on.

Reasons why the refrigerator does not cool, but the freezer works

Of course, the worst thing is when the freezer breaks. In this case, the pressing question arises of what to do with frozen food. Meat, fish and vegetables are those foods that, after defrosting, are suitable for consumption for no more than two days.

If your freezer breaks down in the winter, you can take the food out to the balcony. A bowl of ice water will help you keep your food fresh in the summer.

However, if the refrigerator compartment does not cool, this is also a big problem. Dairy products and ready-made foods are stored in this compartment. Of course, in the cold season you can keep them fresh for several days, but in the summer it only takes a couple of hours for the food to spoil.

The refrigerator may not cool food due to a poorly closed door.

Why did the refrigerator compartment stop working?

  1. The most common reason why the refrigerator compartment may not work is that the door is not tightly closed. The problem may lie either in your carelessness or in contamination of the rubber seal.
  2. If your refrigerator does not have a No Frost system, then it may not cool food well because you have not defrosted it for a long time. In this case, some parts of the unit become covered with a crust of ice and cannot function normally.
  3. The fact that your refrigerator is warm may be a consequence of incorrectly set temperature conditions. For example, if at the maximum cooling level, there is a very high temperature in the room where the refrigerator is located. In this case, the compressor may not be able to cope with the load placed on it.

These are the main reasons why the refrigerator compartment may not work, while the freezer is functioning normally. There are also more serious preconditions for a refrigerator to break down, but usually both chambers of the unit fail.

Schematic diagram of the Indesit Full No Frost refrigerator

Otherwise, the compressor and pipes will go bad, which means a new refrigerator without options.


New rubber gaskets can be secured around the perimeter of the door using glue or epoxy resin. Repairs are sometimes possible in a specialized workshop.


In this mode, the timer is powered not directly, but through the heater and compressor winding. If it is tight or stuck, there will be a plastic plug on the axle at the front or back; perhaps under a company sticker.


If the blades of the device do not rotate, it should be replaced. It can be almost invisible.


I understand a little about electromechanics and I understand that the system seems to have remained the same and the principle is the same, but I would still like to know if that’s why the refrigerator didn’t have a repeat. If it is impossible to remove the tube, you should try to clean it with the brush included in the kit. Only the bimetallic thermostat 3 can turn off the timer.


This will help to operate the device correctly and extend its service life. You need to arm yourself with a level and correct the position of the device using the adjustable legs. Modern Indesit refrigerators operate almost silently. This way the refrigerator does not overheat. Whatever the reason, repairs should not be delayed.

Control board Most often, capacitors deteriorate due to constant voltage surges, so to prevent such repairs in the future, it is better to connect the refrigerator through a stabilizer. Since the cheapest and most reliable compressor drive will be a single-phase asynchronous electric motor with a magnetic start, it will require a starting and protective device in case of a starting circuit failure, see. The constant presence of foreign odors in the refrigerator is usually caused by a violation of the operating rules. It turns on again no earlier than after a minute and then turns itself off. Then let’s look: No Frost refrigerators most often also have a compressor fan.

The electrical circuit of the refrigerator that powers the fan is called, and the movement of the blades is tested. Of course, there is a big difference in the components, but the principle is the same and if you understand it, then it will not be difficult for you to deal with the malfunction. The kit, in addition to 2 L-shaped blanks for the seal itself, must include a pair of connecting flat corners and a tube of special glue. Therefore, below we will describe the typical structure of the most susceptible to failure components in interaction with associated ones and methods for their repair. Figure 4. Refrigerator wiring in detail without know frost

Let your refrigerator last a long time

And finally, a few important points, taking into account which you will extend the life of the “snow-white Italian assistant” (and, of course, the upper chamber):

  • observe the temperature regime. Place the refrigerator away from radiators, the stove and direct sunlight - why force the compressor to wear out. In addition, rubber seals deteriorate faster due to heat;
  • Set the thermostat to medium. Make sure that the “fast freezing” mode is not set constantly;
  • the refrigerator must stand level and stable to prevent excessive vibration;
  • there must be a distance of at least 5 cm from the wall of the refrigerator to the wall and pieces of furniture;
  • Clean the inside of the refrigerator every six months. To do this, disconnect the device from the network. Wipe the inside of the walls with a wet cloth without detergents. You can add lemon juice or a little vinegar to the water - this will remove the unpleasant odor and allow you to better clean the refrigerator compartment. Afterwards, you can wipe the shelves and walls with a clean absorbent cloth and turn on the refrigerator;
  • Do not crowd the back wall of the refrigerator with dishes and food. This will allow water droplets to flow into the drainage system while leaving the drain hole open.

According to experts, every sixth apartment has an Indesit refrigerator. This brand is chosen for its superior food storage, cost-effectiveness, and excellent performance. Those rare troubles that do sometimes happen are successfully and quickly eliminated by specialists. High-quality equipment and professional service are your confidence in the future for many years!

ALM-Repair - repair of Indesit refrigerators Phones: (044) 2094250, (067) 2175668 Website: https://alm-remont.com.ua/

The temperature sensor in the Indesit refrigerator is broken: how to fix it?

The temperature sensor may also be the reason why the Indesit refrigerator does not work.

Signs:

  • No matter how you adjust the temperature, the compressor still does not start . In older models, all chambers do not freeze. In new Indesit, the refrigerator may not work, but the freezer does. There is light and sound notification can be in electronically controlled units. The motor behaves this way because there is something wrong with the temperature sensor. The circuit between it and the compressor is broken. And the latter does not receive the necessary commands - it does not start the cold.
  • The refrigerator does not cool, but the freezer works for Indesit with 2 chambers . And everything in a single-chamber refrigerator does not freeze, that is, the temperature in the entire refrigerator is high. If you have a “smart” model, it may start beeping. A broken sensor mistakenly signals that the temperature is correct and allows the engine to turn on to start the cold.
  • The Indesit refrigerator constantly works and does not turn off, while it freezes more than necessary . A faulty sensor reports that the temperature is higher than it should be, the compressor starts working even harder to reduce the temperature.

What to do? Contact service for a replacement part.

Rating
( 2 ratings, average 4.5 out of 5 )
Did you like the article? Share with friends:
For any suggestions regarding the site: [email protected]
Для любых предложений по сайту: [email protected]